  • Part No.AM22CWCMBAR/1500A
    ManufacturerASHCROFT
    Size2Mb
    Pages9 pages
    DescriptionATE-2 Handheld Calibrator
    Datasheet Summary with AI

    1. General Information & Pressure Measurement:

    ️· Product: ATE-2 Handheld Calibrator
    ️· Function: A portable device for calibrating pressure and temperature instruments.
    ️· Pressure Measurement details (not fully detailed, but mentions):
    - Broad range of pressure types and units.
    - High accuracy.
    - Multiple pressure connections. (Likely includes various adapters for different fittings).

    2. RTD (Resistance Temperature Detector) Temperature Measurement:

    ️· Module Needed: AM2-RTD interface module
    ️· Units: °C, °F, °K, °R
    ️· Resolution: 1, 0.1, or 0.01 degrees selectable, or "Auto" mode (chooses best resolution)
    ️· Accuracy: Not explicitly stated in this excerpt, but would be a key specification.
    ️· Important: Requires customer-supplied RTD probes.

    3. Thermocouple Temperature Measurement:

    ️· Module Needed: AM2-TC1 interface module
    ️· Thermocouple Types: Supports 8 common thermocouple types (specific types not listed).
    ️· Reference Junctions: Can use internal or external reference junctions.
    ️· Units: °C, °F, °K, °R, millivolts
    ️· Resolution: 1, 0.1, or 0.01 degrees selectable, or "Auto" mode. 0.001 millivolts for millivolt readings.
    ️· Connection: Requires miniature thermocouple connectors (Omega type SMP).
    ️· Important: Requires customer-supplied thermocouple probes.
    ️· Accuracy: System accuracy includes base unit and interface module (but doesn't include thermocouple probe inaccuracy - consult manufacturer specs).
    ️· Conversion Factors: Provided for converting between temperature scales.

    4. General Specifications & Notes:

    ️· Accuracy: Accuracy is a critical specification, and while mentioned as system accuracy for temp measurements, specific numbers would be in the full datasheet.
    ️· Manual/Automatic Modes: Often selectable for reference junctions and resolution.
    ️· Customer-Supplied Probes: RTDs and thermocouples are *not* included with the calibrator; users must provide their own.
    ️· Subject to Change: All specifications are subject to change without notice.
    ️· Conversion Factors: Conversion from Celsius to Fahrenheit, Kelvin and Rankine

    Overall Impression:

    1. General Information & Pressure Measurement:

    ️· Product: ATE-2 Handheld Calibrator
    ️· Function: A portable device for calibrating pressure and temperature instruments.
    ️· Pressure Measurement details (not fully detailed, but mentions):
    - Broad range of pressure types and units.
    - High accuracy.
    - Multiple pressure connections. (Likely includes various adapters for different fittings).

    2. RTD (Resistance Temperature Detector) Temperature Measurement:

    ️· Module Needed: AM2-RTD interface module
    ️· Units: °C, °F, °K, °R
    ️· Resolution: 1, 0.1, or 0.01 degrees selectable, or "Auto" mode (chooses best resolution)
    ️· Accuracy: Not explicitly stated in this excerpt, but would be a key specification.
    ️· Important: Requires customer-supplied RTD probes.

    3. Thermocouple Temperature Measurement:

    ️· Module Needed: AM2-TC1 interface module
    ️· Thermocouple Types: Supports 8 common thermocouple types (specific types not listed).
    ️· Reference Junctions: Can use internal or external reference junctions.
    ️· Units: °C, °F, °K, °R, millivolts
    ️· Resolution: 1, 0.1, or 0.01 degrees selectable, or "Auto" mode. 0.001 millivolts for millivolt readings.
    ️· Connection: Requires miniature thermocouple connectors (Omega type SMP).
    ️· Important: Requires customer-supplied thermocouple probes.
    ️· Accuracy: System accuracy includes base unit and interface module (but doesn't include thermocouple probe inaccuracy - consult manufacturer specs).
    ️· Conversion Factors: Provided for converting between temperature scales.

    4. General Specifications & Notes:

    ️· Accuracy: Accuracy is a critical specification, and while mentioned as system accuracy for temp measurements, specific numbers would be in the full datasheet.
    ️· Manual/Automatic Modes: Often selectable for reference junctions and resolution.
    ️· Customer-Supplied Probes: RTDs and thermocouples are *not* included with the calibrator; users must provide their own.
    ️· Subject to Change: All specifications are subject to change without notice.
    ️· Conversion Factors: Conversion from Celsius to Fahrenheit, Kelvin and Rankine

    Overall Impression:

    Part No.AM22CWCMBAR/1500A
    ManufacturerASHCROFT
    Size2Mb
    Pages9 pages
    DescriptionATE-2 Handheld Calibrator
    Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

    Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com